IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Marihuana Potency Analysis by
High Performance Liquid Chromatography

Testing Accreditation #: 77802 Test Certificate #: 153390-001
Client Name, Sample Details

@caregiverpharms
Westland, MI 48185
Sample: Hawaiian Unicorn
Type: Flower
Method: FE04U12 HPLC-UV

Test Conditions

Prepsheet ID#: MIP250204a
Scale: XS205-MI1
Temp: 22.5 °C
Baro Pressure: 979.6 hPa
Analyst: MEH
Technician: ARH

Sample ID#: 153390

Harvest/Process Date: 02/03/2025
Serving Size (g): 1
Date Received: 02/03/2025
Test Date: 02/05/2025
Valid Through: 02/06/2026
Report Issued: 02/06/2025

Sample #153390
Sample #153390 Sample #153390
Test
Compounds
Δ9-THC THCA Δ8-THC CBD CBDA CBG CBGA CBN CBC CBL THCV CBDV Total
Cannabinoids*
Total THC Total CBD Calc Max Total
Cannabinoids*
Amount (%) 0.2 17.5 N/D N/D N/D N/D 0.7 N/D N/D N/D N/D N/D 18.4 15.6 0.0 16.2
Amount (mg/g) 2.0 175.2 N/D N/D N/D N/D 6.9 N/D N/D N/D N/D N/D 184.1 155.7 0.0 161.7
Amount per Serving (mg) 2 175.2 N/D N/D N/D N/D 6.9 N/D N/D N/D N/D N/D 184.1  
LOQ (mg/g) 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9   %Decarb. THC CBD
±%RPD 6.44% 1.66% 1.87% 0.09% 0.13% 0.35% 0.61% 0.08% 0.48% 1.14% 0.12% 0.41% 1 N/A

LOQ = Limit of Quantitation; %RPD = Relative Percent Deviation; %RSD = Relative Standard Deviation; N/D = Not Detected. *Designates values that are not currently included in the accredited scope of Iron Laboratories. *** Designates tests that use the SOP FE-45 (water activity meter) method. FE-45 is performed using AOAC 966.02 and 32.004-32.009.

FE-45 has relative expanded (k=2) uncertainties of 1.098% for moisture, 1.754% for water activity for unprocessed plant materials, and 13.102% for water activity for infused products.

Vitamin E acetate analysis has a relative expanded (k=2) uncertainty of 18.614%. Sample fails vitamin E acetate if VEA>100 ug/g.

Total THC and CBD is the calculated sum of Δ9-THC and Δ8-THC or CBD plus the amount of THC or CBD derived from THCA or CBDA, respectively.

These values are calculated by applying a molar correction factor of 0.877 to the THCA or the CBDA value. Calc Max Total Cannabinoids is the sum of Total THC, Total CBD, CBN, Total CBG, CBC, THCV, CBDV, and CBL. Total CBG is calculated as CBG plus CBGA*0.878 (the molar correction factor for CBGA to CBG conversion). %Decarb. THC and CBD refer to the percentage of Δ9-THC or CBD relative to THCA or CBDA, respectively.

Potency Action Limits
Product Type Action Limit
Concentrates & Vapes Delta-8 concentration cannot exceed 10%
Infused Products

Delta-8 cannot exceed 10% of the maximum THC limits;

Homogeneity must be ≤15% RSD; Variance must be ≤10%

Maximum THC (Sum of Delta-8 and Delta-9) Concentrations for Infused Products (in mg)

 Category

Medical

(Per Dose)

Medical

(Per Container)

Adult-Use

(Per Dose)

Adult-Use

(Per Container)

Infused edibles (gummies, baked goods, drink enhancers, syrup) 50 200 10 200
Medicinal products (capsules, tinctures, oil-based drops) 100 2000 10 200
Medicinal Products not consumed orally (suppositories, tampons, transdermal patches) 100 2000 100 2000
Beverages 10 100 10 100

This sample has not undergone random sampling and has not been tested for compliant state, batch representative testing. These results should therefore be used for research and development or quality control purposes only. Results apply to the sample as received.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

ARH - LM Iron laboratories ARH - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 1

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

QC Report

Testing Accreditation #: 77802 Test Certificate #: 153390-001
Client Name, Sample Details

@caregiverpharms
Westland, MI 48185
Sample: Hawaiian Unicorn
Type: Flower
Method: FE04U12 HPLC-UV

Test Conditions

Prepsheet ID#: MIP250204a
Scale: XS205-MI1
Temp: 22.5 °C
Baro Pressure: 979.6 hPa
Analyst: MEH
Technician: ARH

Sample ID#: 153390

Harvest/Process Date: 02/03/2025
Serving Size (g): 1
Date Received: 02/03/2025
Test Date: 02/05/2025
Valid Through: 02/06/2026
Report Issued: 02/06/2025

Sample #153390
Target Compound Name Method Blank (μg/g) LCS Spike (μg/g) LCS Amount (μg/g) Percent Recovery (%) LCS LCS Duplicate Amount (μg/g) Percent Recovery (%) LCSD Relative Percent Difference (%) QC Flag
Δ9-THC 0 4.63901 4.19878 90.51 4.47798 96.53 6.44%
THCA 0 4.68277 4.4782 95.63 4.40445 94.06 1.66%
Δ8-THC 0 4.56259 4.4184 96.84 4.50161 98.66 1.87%
CBD 0 4.65437 4.5871 98.55 4.59132 98.65 0.09%
CBDA 0 4.58178 4.55689 99.46 4.56293 99.59 0.13%
CBG 0 4.61186 4.46845 96.89 4.45276 96.55 0.35%
CBGA 0 4.61809 4.53556 98.21 4.5079 97.61 0.61%
CBN 0 4.53885 4.54809 100.20 4.54441 100.12 0.08%
CBC 0 4.47375 4.47823 100.10 4.49957 100.58 0.48%
CBCA N/A 0 0 0.00 0 0.00 0% N/A
CBL 0 4.54624 4.53802 99.82 4.48656 98.69 1.14%
THCV 0 4.43496 4.4357 100.02 4.43055 99.90 0.12%
CBDV 0 5.51515 4.48906 81.40 4.47083 81.06 0.41% LR

N.D. = Not Detected

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

This sample has not undergone random sampling and has not been tested for compliant state, batch representative testing. These results should therefore be used for research and development or quality control purposes only. Results apply to the sample as received.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

ARH - LM Iron laboratories ARH - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 1