IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Marihuana Potency Analysis by
High Performance Liquid Chromatography

Testing Accreditation #: 77802 Test Certificate #: 149255-001
Client Name, Sample Details

Agronomos Luxury Loud AU-G-C-000844
Detroit, MI 48216
Sample: Twizzler
License: AU-G-C-000844
Type: Adult Use Flower
Method: FE04U12 HPLC-UV
Metrc Test Pkg#: 1A405030002EA19000003921
Metrc Source Pkg#: 1A405030002EA19000003909
***Water Activity: 0.51

Test Conditions

Prepsheet ID#: MIP240912d
Scale: XS205-MI1
Temp: 21.3 °C
Baro Pressure: 984.8 hPa
Analyst: MEH
Technician: ARH

Sample ID#: 149255

Harvest/Process Date: 09/11/2024
Serving Size (g): 1
Date Received: 09/11/2024
Test Date: 09/12/2024
Valid Through: 09/13/2025
Report Issued: 09/17/2024

Sample #149255
Sample #149255 Sample #149255
Test
Compounds
Δ9-THC THCA Δ8-THC CBD CBDA CBG CBGA CBN CBC CBL THCV CBDV Total
Cannabinoids*
Total THC Total CBD Calc Max Total
Cannabinoids*
Amount (%) 0.6 27.8 N/D N/D 0.1 0.2 0.9 N/D N/D N/D N/D N/D 29.5 24.9 0.1 26.0
Amount (mg/g) 5.7 277.8 N/D N/D 1.3 1.5 9.08 N/D N/D N/D N/D N/D 295.38 249.3 1.2 259.9
Amount per Serving (mg) 5.7 277.8 N/D N/D 1.3 1.5 9.08 N/D N/D N/D N/D N/D 295.4  
LOQ (mg/g) 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75   %Decarb. THC CBD
±%RPD 5.55% 0.45% 2.77% 0.89% 0.06% 1.87% 0.41% 1.24% 0.48% 0.78% 0.54% 1.00% 2 0%

Sample passes for water activity (sample fails if Aw>0.65). Water activity is measured utilizing SOP FE-45 (water activity meter).

LOQ = Limit of Quantitation; %RPD = Relative Percent Deviation; %RSD = Relative Standard Deviation; N/D = Not Detected. *Designates values that are not currently included in the accredited scope of Iron Laboratories. *** Designates tests that use the SOP FE-45 (water activity meter) method. FE-45 is performed using AOAC 966.02 and 32.004-32.009.

FE-45 has relative expanded (k=2) uncertainties of 1.098% for moisture, 1.754% for water activity for unprocessed plant materials, and 13.102% for water activity for infused products.

Vitamin E acetate analysis has a relative expanded (k=2) uncertainty of 18.614%. Sample fails vitamin E acetate if VEA>100 ug/g.

Total THC and CBD is the calculated sum of Δ9-THC and Δ8-THC or CBD plus the amount of THC or CBD derived from THCA or CBDA, respectively.

These values are calculated by applying a molar correction factor of 0.877 to the THCA or the CBDA value. Calc Max Total Cannabinoids is the sum of Total THC, Total CBD, CBN, Total CBG, CBC, THCV, CBDV, and CBL. Total CBG is calculated as CBG plus CBGA*0.878 (the molar correction factor for CBGA to CBG conversion). %Decarb. THC and CBD refer to the percentage of Δ9-THC or CBD relative to THCA or CBDA, respectively.

Potency Action Limits
Product Type Action Limit
Concentrates & Vapes Delta-8 concentration cannot exceed 10%
Infused Products

Delta-8 cannot exceed 10% of the maximum THC limits;

Homogeneity must be ≤15% RSD; Variance must be ≤10%

Maximum THC (Sum of Delta-8 and Delta-9) Concentrations for Infused Products (in mg)

 Category

Medical

(Per Dose)

Medical

(Per Container)

Adult-Use

(Per Dose)

Adult-Use

(Per Container)

Infused edibles (gummies, baked goods, drink enhancers, syrup) 50 200 10 200
Medicinal products (capsules, tinctures, oil-based drops) 100 2000 10 200
Medicinal Products not consumed orally (suppositories, tampons, transdermal patches) 100 2000 100 2000
Beverages 10 100 10 100

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

ARH - LM Iron laboratories ARH - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 6

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

QC Report

Testing Accreditation #: 77802 Test Certificate #: 149255-001
Client Name, Sample Details

Agronomos Luxury Loud AU-G-C-000844
Detroit, MI 48216
Sample: Twizzler
License: AU-G-C-000844
Type: Adult Use Flower
Method: FE04U12 HPLC-UV
Metrc Test Pkg#: 1A405030002EA19000003921
Metrc Source Pkg#: 1A405030002EA19000003909
***Water Activity: 0.51

Test Conditions

Prepsheet ID#: MIP240912d
Scale: XS205-MI1
Temp: 21.3 °C
Baro Pressure: 984.8 hPa
Analyst: MEH
Technician: ARH

Sample ID#: 149255

Harvest/Process Date: 09/11/2024
Serving Size (g): 1
Date Received: 09/11/2024
Test Date: 09/12/2024
Valid Through: 09/13/2025
Report Issued: 09/17/2024

Sample #149255
Target Compound Name Method Blank (μg/g) LCS Spike (μg/g) LCS Amount (μg/g) Percent Recovery (%) LCS LCS Duplicate Amount (μg/g) Percent Recovery (%) LCSD Relative Percent Difference (%) QC Flag
Δ9-THC 0 5.68214 5.75308 101.25 6.08177 107.03 5.55%
THCA 0 5.30273 5.26994 99.38 5.24634 98.94 0.45%
Δ8-THC 0 5.56507 5.69608 102.35 5.54069 99.56 2.77%
CBD 0 5.14474 5.30023 103.02 5.34737 103.94 0.89%
CBDA 0 5.48439 5.25908 95.89 5.25586 95.83 0.06%
CBG 0 5.39314 5.51375 102.24 5.61811 104.17 1.87%
CBGA 0 5.3635 5.30459 98.90 5.32653 99.31 0.41%
CBN 0 5.36809 5.46145 101.74 5.39432 100.49 1.24%
CBC 0 5.31391 5.31463 100.01 5.34044 100.50 0.48%
CBCA N/A 0 0 0.00 0 0.00 0% N/A
CBL 0 5.31963 5.33257 100.24 5.29128 99.47 0.78%
THCV 0 5.42546 5.40609 99.64 5.37677 99.10 0.54%
CBDV 0 5.31234 5.32696 100.28 5.27394 99.28 1.00%

N.D. = Not Detected

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

ARH - LM Iron laboratories ARH - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 6

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Pesticide Analysis by
Mass Spectrometer

Testing Accreditation #: 77802 Test Certificate #: 149255-001
Client Name, Sample Details

Agronomos Luxury Loud AU-G-C-000844
Detroit, MI 48216
Sample: Twizzler
License: AU-G-C-000844
Type: Adult Use Flower
Method: FE-52 (EN 15662 & AOAC 2007.01)
Metrc Test Pkg#: 1A405030002EA19000003921
Metrc Source Pkg#: 1A405030002EA19000003909

Test Conditions

Prepsheet ID#: MIPS240916a
Scale: XS205-MI1
Temp: 22.4 °C
Baro PE: 982.7 hPa
Analyst: OSB
Technician: OSB

Sample ID#: 149255

Harvest/Process Date: 09/11/2024
Serving Size (g): 1
Date Received: 09/11/2024
Test Date: 09/16/2024
Valid Through: 09/16/2025
Report Issued: 09/17/2024

Sample #149255
Compound MRL (µg/g) LOD (µg/g) Status (µg/g)   Compound MRL (µg/g) LOD (µg/g) Status (µg/g)
Aldicarb 0.400 0.200 Pass/<LOD Abamectin**** 0.500 0.250 Pass/<LOD
Acephate 0.400 0.200 Pass/<LOD Acequinocyl 2.000 1.000 Pass/<LOD
Acetamiprid 0.200 0.100 Pass/<LOD Azoxystrobin 0.200 0.100 Pass/<LOD
Bifenazate 0.200 0.100 Pass/<LOD Bifenthrin 0.200 0.100 Pass/<LOD
Boscalid 0.400 0.200 Pass/<LOD Carbaryl 0.200 0.100 Pass/<LOD
Carbofuran 0.200 0.100 Pass/<LOD Chlorantraniliprole 0.200 0.100 Pass/<LOD
Chlorfenapyr 1.000 0.500 Pass/<LOD Chlorpyrifos 0.200 0.100 Pass/<LOD
Clofentezine 0.200 0.100 Pass/<LOD Cyfluthrin** 1.000 0.500 Pass/<LOD
Cypermethrin*** 1.000 0.500 Pass/<LOD Daminozide 1.000 0.500 Pass/<LOD
DDVP (Dichlorvos) 1.000 0.500 Pass/<LOD Diazinon 0.200 0.100 Pass/<LOD
Dimethoate 0.200 0.100 Pass/<LOD Ethoprophos 0.200 0.100 Pass/<LOD
Etofenprox 0.400 0.200 Pass/<LOD Etoxazole 0.200 0.100 Pass/<LOD
Fenoxycarb 0.200 0.100 Pass/<LOD Fenpyroximate 0.400 0.200 Pass/<LOD
Fipronil 0.400 0.200 Pass/<LOD Flonicamid 1.000 0.500 Pass/<LOD
Fludioxonil 0.400 0.200 Pass/<LOD Hexythiazox 1.000 0.500 Pass/<LOD
Imazalil 0.200 0.100 Pass/<LOD Imidacloprid 0.400 0.200 Pass/<LOD
Kresoxim Methyl 0.400 0.200 Pass/<LOD Malathion 0.200 0.100 Pass/<LOD
Metalaxyl 0.200 0.100 Pass/<LOD Methiocarb 0.200 0.100 Pass/<LOD
Methomyl 0.400 0.200 Pass/<LOD Methyl Parathion 0.200 0.100 Pass/<LOD
MGK-264‡ 0.200 0.100 Pass/<LOD Myclobutanil 0.200 0.100 Pass/<LOD
Naled 0.500 0.250 Pass/<LOD Oxamyl 1.000 0.500 Pass/<LOD
Paclobutrazol 0.400 0.200 Pass/<LOD Permethrins† 0.200 0.100 Pass/<LOD
Phosmet 0.200 0.100 Pass/<LOD Piperonyl Butoxide 100.000 1.900 Not Tested
Prallethrin 0.200 0.100 Pass/<LOD Propiconazole 0.400 0.200 Pass/<LOD
Propoxur 0.200 0.100 Pass/<LOD Pyrethrins* 1.000 0.500 Pass/<LOD
Pyridaben 0.200 0.100 Pass/<LOD Spinosad***** 0.200 0.100 Pass/<LOD
Spiromesifen 0.200 0.100 Pass/<LOD Spirotetramat 0.200 0.100 Pass/<LOD
Spiroxamine‡ 0.400 0.200 Pass/<LOD Tebuconazole 0.400 0.200 Pass/<LOD
Thiacloprid 0.200 0.100 Pass/<LOD Thiamethoxam 0.200 0.100 Pass/<LOD
Trifloxystrobin 0.200 0.100 Pass/<LOD

* Pyrethrins are reported as the sum of Jasmolin I, Cinerin I, and Pyrethrin I
** Cyfluthrins are reported as the sum of isomers Cyfluthrin I, II, III, and IV
*** Cypermethrins are reported as the sum of isomers Cypermethrin I, II, III, and IV
**** Abamectin is reported as the sum of Avermectin B1a and Avermectin B1b
***** Spinosad is reported as the sum of Spinosyn A and Spinosyn D
† Permethrin and Prallethrin are reported as the sum of cis and trans isomers
‡ MGK-264 and Spiroximine are reported as the sum of isomers I and II
MRL - Maximum Residue Limit; LOD - Limit of Detection

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

ARH - LM Iron laboratories ARH - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 6

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Pesticide QC Report

Testing Accreditation #: 77802 Test Certificate #: 149255-001
Client Name, Sample Details

Agronomos Luxury Loud AU-G-C-000844
Detroit, MI 48216
Sample: Twizzler
License: AU-G-C-000844
Type: Adult Use Flower
Method: FE-52 (EN 15662 & AOAC 2007.01)
Metrc Test Pkg#: 1A405030002EA19000003921
Metrc Source Pkg#: 1A405030002EA19000003909

Test Conditions

Prepsheet ID#: MIPS240916a
Scale: XS205-MI1
Temp: 22.4 °C
Baro PE: 982.7 hPa
Analyst: OSB
Technician: OSB

Sample ID#: 149255

Harvest/Process Date: 09/11/2024
Serving Size (g): 1
Date Received: 09/11/2024
Test Date: 09/16/2024
Valid Through: 09/16/2025
Report Issued: 09/17/2024

Sample #149255
Target Compound Name Method Blank (μg/g) QC Spike (μg/g) Matrix Spike (μg/g) Matrix Spike Duplicate (μg/g) MS recovery% MSD recovery% Relative Percent Difference (%) QC Flag
Acephate N.D. 1 0.728 0.679 72.80 67.90 6.97
Acequinocyl N.D. 1 0.477 0.461 47.70 46.10 3.41 LR
Acetamiprid N.D. 1 1.72 1.82 172.00 182.00 5.65 HR
Aldicarb N.D. 1 1.47 1.54 147.00 154.00 4.65 HR
Avermectin B1a N.D. 1 0.773 0.713 77.30 71.30 8.08
Azoxystrobin N.D. 1 1.45 1.42 145.00 142.00 2.09 HR
Bifenazate N.D. 1 1.12 1.06 112.00 106.00 5.50
Bifenthrin N.D. 1 1.08 1.22 108.00 122.00 12.17 HR
Boscalid N.D. 1 0.715 0.634 71.50 63.40 12.01
Carbaryl N.D. 1 1.37 1.53 137.00 153.00 11.03 HR
Carbofuran N.D. 1 1.52 1.44 152.00 144.00 5.41 HR
Chlorantraniliprole N.D. 1 1.17 1.13 117.00 113.00 3.48
Chlorfenapyr N.D. 1 1.13 1.15 113.00 115.00 1.75
Chlorpyriphos N.D. 1 0.65 0.622 65.00 62.20 4.40
Clofentezine N.D. 1 1.02 0.994 102.00 99.40 2.58
Cyfluthrin N.D. 1 1.27 1.17 127.00 117.00 8.20 HR
Cypermethrin N.D. 1 1.09 1.03 109.00 103.00 5.66
Daminoside N.D. 1 0.0782 0.0785 7.82 7.85 0.38 LR
Diazanon N.D. 1 1.29 1.22 129.00 122.00 5.58 HR
Dichlorvos N.D. 1 1.39 1.28 139.00 128.00 8.24 HR
Dimethoate N.D. 1 1.54 1.46 154.00 146.00 5.33 HR
Ethoprophos N.D. 1 1.25 1.28 125.00 128.00 2.37 HR
Etofenprox N.D. 1 1.05 1.05 105.00 105.00 0.00
Etoxazole N.D. 1 0.863 0.838 86.30 83.80 2.94
Fenoxycarb N.D. 1 1.3 1.22 130.00 122.00 6.35 HR
Fenpyroximate N.D. 1 1.22 1.19 122.00 119.00 2.49 HR
Fipronil N.D. 1 1.34 1.24 134.00 124.00 7.75 HR
Flonicamid N.D. 1 1.45 1.45 145.00 145.00 0.00 HR
Fludioxonil N.D. 1 1.18 1.19 118.00 119.00 0.84
Hexythiazox N.D. 1 0.766 0.709 76.60 70.90 7.73
Imazalil N.D. 1 1.09 1.06 109.00 106.00 2.79
Imidacloprid N.D. 1 1.28 1.23 128.00 123.00 3.98 HR
Kresoxim-methyl N.D. 1 1.12 1.03 112.00 103.00 8.37
Malathion N.D. 1 0.867 0.889 86.70 88.90 2.51
Metalaxyl N.D. 1 1.44 1.48 144.00 148.00 2.74 HR
Methiocarb N.D. 1 1.35 1.49 135.00 149.00 9.86 HR
Methomyl N.D. 1 1.03 0.93 103.00 93.00 10.20
MGK-264 N.D. 1 0.971 1.075 97.10 107.50 10.17
Myclobutanil N.D. 1 1.2 1.17 120.00 117.00 2.53
Naled (dibrom) N.D. 1 0.441 0.5 44.10 50.00 12.54 LR
Oxamyl N.D. 1 1.56 1.53 156.00 153.00 1.94 HR
Paclobutrazol N.D. 1 1.27 1.26 127.00 126.00 0.79 HR
Parathion-methyl N.D. 1 1.04 1.07 104.00 107.00 2.84
Permethrins N.D. 1 1.093 1.113 109.30 111.30 1.81
Phosmet N.D. 1 0.978 0.893 97.80 89.30 9.09
Piperonyl butoxide N/A N/A N/A N/A nan nan N/A
Prallethrin N.D. 1 1.19 1.19 119.00 119.00 0.00
Propiconazole N.D. 1 0.76 0.744 76.00 74.40 2.13
Propoxur N.D. 1 1.57 1.51 157.00 151.00 3.90 HR
Pyrethrin N.D. 1 0.832 0.784 83.20 78.40 5.94
Pyridaben N.D. 1 0.87 0.837 87.00 83.70 3.87
SpinosynA N.D. 0.82 0.856 0.807 104.39 98.41 5.89
SpinosynD N.D. 0.18 0.241 0.229 133.89 127.22 5.11 HR
Spiromesifen N.D. 1 0.493 0.501 49.30 50.10 1.61 LR
Spirotetramat N.D. 1 0.772 0.768 77.20 76.80 0.52
Spiroxamine N.D. 1 1.33 1.32 133.00 132.00 0.75 HR
Tebuconazole N.D. 1 1.27 1.23 127.00 123.00 3.20 HR
Thiacloprid N.D. 1 1.23 1.18 123.00 118.00 4.15 HR
Thiamethoxam N.D. 1 1.28 1.3 128.00 130.00 1.55 HR
Trifloxystrobin N.D. 1 1.47 1.41 147.00 141.00 4.17 HR

N.D. = Not Detected

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 30%

R = indicates compound recovery of matrix spike was outside the methods acceptable limits. (60-120%) Low recovery could indicate there is actually more compound present than detected; while high recoveries should be scrutinized for possible fails as more compound may be detected than is actually residual on the sample.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

ARH - LM Iron laboratories ARH - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 3 of 6

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Microbiology Analysis

Testing Accreditation #: 77802 Test Certificate #: 149255-001
Client Name, Sample Details

Agronomos Luxury Loud AU-G-C-000844
Detroit, MI 48216
Sample: Twizzler
License: AU-G-C-000844
Type: Adult Use Flower
Metrc Test Pkg#: 1A405030002EA19000003921
Metrc Source Pkg#: 1A405030002EA19000003909

Test Conditions

Scale: Pioneer-MI1
Temp: 23.3 °C
Baro Pressure: 984.3 hPa
Analyst: EDB
Technician: EDB

Sample ID#: 149255

Harvest/Process Date: 09/11/2024
Serving Size (g): 1
Date Received: 09/11/2024
Test Date: 09/13/2024
Valid Through: 09/13/2025
Report Issued: 09/16/2024

Sample #149255
Test Method MCFU (CFU/g) LOD (CFU/g) Status (CFU/g)
Total Aerobic Not Tested N/A 0 Not Tested
Yeast & Mold FE-66 (MPN) 100,001 100 Pass/<LOD
Bile-tolerant gram-negative bacteria Not Tested N/A 0 Not Tested
Total Coliforms FE-66 (MPN) 1,001 100 Pass/<LOD
E. Coli FE-65 (PCR) 1 1 Pass/Not Present
Salmonella FE-65 (PCR) 1 1 Pass/Not Present
Aspergillus spp. FE-65 (PCR) 1 1 Pass/Not Present

E. coli test screens exclusively for Shiga toxin-producing E. coli. TNTC values for yeast and mold are >150,000 CFU/g. TNTC values for total coliforms are >15,000 CFU/g. The maximum relative uncertainty is 6% for PCR and 40% for MPN.

TNTC = Too Numerous To Count. Maximum Colony Forming Units (MCFU) represents the minimum value that a test would need to achieve in order to be considered a failed result (if applicable). LOD is the Limit of Detection for the method. CFU/g = Colony Forming Units per gram. Aspergillus spp. consists of A. flavus, A. fumigatus, A. niger, and A. terreus.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 4 of 6

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Bio Analysis by
Microscopic Visual Inspection

Testing Accreditation #: 77802 Test Certificate #: 149255-001
Client Name, Sample Details

Agronomos Luxury Loud AU-G-C-000844
Detroit, MI 48216
Sample: Twizzler
License: AU-G-C-000844
Type: Adult Use Flower
Method: FE02 Microscope Dissection
Metrc Test Pkg#: 1A405030002EA19000003921
Metrc Source Pkg#: 1A405030002EA19000003909

Test Conditions

Analyst: MJB
Technician: MJB

Sample ID#: 149255

Harvest/Process Date: 09/11/2024
Serving Size (g): 1
Date Received: 09/11/2024
Test Date: 09/16/2024
Valid Through: 09/16/2025
Report Issued: 09/16/2024

Sample #149255
Sample #149255 Sample #149255
Severity Rating
Mold and Mildew 0 Pass
Mites (not Russet) 0 Pass
Russet Mites 0 Pass
Thrips 0 Pass
Aphids 0 Pass
Other Pests 0 Pass
Other Organic Matter 0 Pass
Inorganic Matter 0 Pass
Total Organic Foreign Matter <2% Pass
Inorganic Foreign Matter 0% Pass
Stem Material <5% Pass
Severity Rating Key
Correlating %FM ≤2% FM >2% FM
Severity Rating 0 None 1 Mild 2 Moderate 3 Severe Units
Mold and Mildew <2 2 3 4+ Locations/g
Mites (not russet) <1 1-5 6-10 11+ Amount/g
Russet Mites <1 1-10 11-50 51+ Amount/g
Thrips <1 1-3 4-5 6+ Amount/g
Aphids <1 1 2-4 5+ Amount/g
Other Pests <1 1-5 6-10 11+ Amount/g
Other Organic Matter <1 1-5 6-10 11+ Amount/g
Inorganic Matter 0 >0 Amount/g

In compliance with the MMFLA regulation, the action limits for foreign matter are as follows; no more that 2% organic matter, 5% stem material, and no presence of inorganic matter. Percent foreign contamination is based off of total surface area.

Scale: PIONEER-MI1.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 5 of 6

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Heavy Metals Analysis

Testing Accreditation #: 77802 Test Certificate #: 149255-001
Client Name, Sample Details

Agronomos Luxury Loud AU-G-C-000844
Detroit, MI 48216
Sample: Twizzler
License: AU-G-C-000844
Type: Adult Use Flower
Method: FE60 ICPMS-MI
Metrc Test Pkg#: 1A405030002EA19000003921
Metrc Source Pkg#: 1A405030002EA19000003909

Test Conditions

Prepsheet ID#: HMMIICP240911fMK
Temp: 23.0 °C
Baro PE: 985.4 hPa
Analyst: MK
Technician: MK

Sample ID#: 149255

Harvest/Process Date: 09/11/2024
Serving Size (g): 1
Date Received: 09/11/2024
Test Date: 09/11/2024
Valid Through: 09/11/2025
Report Issued: 09/12/2024

Sample #149255
Sample #149255 Sample #149255
Test Compound MRL (PPM) LOD (PPM) Status (PPM)
Arsenic 0.4 0.1 Pass/<LOD
Copper 0 1.5 Not Tested
Cadmium 0.4 0.1 Pass/<LOD
Chromium 1.2 0.3 Pass/<LOD
Lead 1 0.25 Pass/<LOD
Mercury 0.2 0.05 Pass/<LOD
Nickel 1 0.25 Pass/<LOD

MRL - Maximum Residue Limit; LOD - Limit of Detection

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 6 of 6

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

QC Report

Testing Accreditation #: 77802 Test Certificate #: 149255-001
Client Name, Sample Details

Agronomos Luxury Loud AU-G-C-000844
Detroit, MI 48216
Sample: Twizzler
License: AU-G-C-000844
Type: Adult Use Flower
Method: FE60 ICPMS-MI
Metrc Test Pkg#: 1A405030002EA19000003921
Metrc Source Pkg#: 1A405030002EA19000003909

Test Conditions

Prepsheet ID#: HMMIICP240911fMK
Temp: 23.0 °C
Baro PE: 985.4 hPa
Analyst: MK
Technician: MK

Sample ID#: 149255

Harvest/Process Date: 09/11/2024
Serving Size (g): 1
Date Received: 09/11/2024
Test Date: 09/11/2024
Valid Through: 09/11/2025
Report Issued: 09/12/2024

Sample #149255
Target Compound Name Method Blank (μg/g) LCS Spike (μg/g) LCS Amount (μg/g) Percent Recovery (%) LCS LCS Duplicate Amount (μg/g) Percent Recovery (%) LCSD QC Flag
Arsenic N/D 0.160 0.174 108.75 0.173 108.13
Cadmium N/D 0.160 0.163 101.88 0.161 100.63
Chromium N/D 0.480 0.483 100.63 0.486 101.25
Copper N/D 2.400 2.473 103.04 2.432 101.33
Lead N/D 0.400 0.425 106.25 0.419 104.75
Mercury N/D 0.080 0.092 115.00 0.084 105.00
Nickel N/D 0.400 0.429 107.25 0.424 106.00

N.D. = Not Detected

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 7 of 6