IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Marihuana Potency Analysis by
High Performance Liquid Chromatography

Testing Accreditation #: 77802 Test Certificate #: 145632-001
Client Name, Sample Details

Ferndale Maize LLC - STIIIZY (AU-P-000253)
Lake Orion, MI 48359
Sample: Distillate 8
License: AU-P-000253
Type: Tincture
Method: FE04 HPLC-UV
Metrc Test Pkg#: 1A405030002A686000159559
Metrc Source Pkg#: 1A405030002A686000159827

Test Conditions

Prepsheet ID#: MIP240223a
Scale: XS205-MI2
Temp: 22.6 °C
Baro Pressure: 981.2 hPa
Analyst: MEH
Technician: ARH

Sample ID#: 145632

Harvest/Process Date: 02/21/2024
Serving Size (g): 1
Date Received: 02/21/2024
Test Date: 02/23/2024
Valid Through: 02/23/2025
Report Issued: 02/26/2024

Sample #145632
Sample #145632 Sample #145632
Test
Compounds
Δ9-THC THCA Δ8-THC CBD CBDA CBG CBGA CBN CBC CBL THCV CBDV Total
Cannabinoids*
Total THC Total CBD Calc Max Total
Cannabinoids*
Amount (%) 88.0 N/D N/D N/D N/D 3.1 N/D 0.4 2.4 N/D 1.2 N/D 95.1 88.0 0.0 95.1
Amount (mg/g) 879.8 N/D N/D N/D N/D 31.1 N/D 3.7 24.4 N/D 11.5 N/D 950.5 879.8 0.0 950.5
Amount per Serving (mg) 879.8 N/D N/D N/D N/D 31.1 N/D 3.7 24.4 N/D 11.5 N/D 950.5  
LOQ (mg/g) 2.84 2.84 2.84 2.84 2.84 2.84 2.84 2.84 2.84 2.84 2.84 2.84   %Decarb. THC CBD
±%RPD 2.34% 0.07% 2.91% 0.06% 0.09% 0.40% 0.46% 0.37% 0.06% 0.29% 0.16% 0.29% 100% N/A

LOQ = Limit of Quantitation; %RPD = Relative Percent Deviation; %RSD = Relative Standard Deviation; N/D = Not Detected. *Designates values that are not currently included in the accredited scope of Iron Laboratories. *** Designates tests that use the SOP FE-45 (water activity meter) method. FE-45 is performed using AOAC 966.02 and 32.004-32.009.

FE-45 has relative expanded (k=2) uncertainties of 1.098% for moisture, 1.754% for water activity for unprocessed plant materials, and 13.102% for water activity for infused products.

Vitamin E acetate analysis has a relative expanded (k=2) uncertainty of 18.614%. Sample fails vitamin E acetate if VEA>100 ug/g.

Total THC and CBD is the calculated sum of Δ9-THC and Δ8-THC or CBD plus the amount of THC or CBD derived from THCA or CBDA, respectively.

These values are calculated by applying a molar correction factor of 0.877 to the THCA or the CBDA value. Calc Max Total Cannabinoids is the sum of Total THC, Total CBD, CBN, Total CBG, CBC, THCV, CBDV, and CBL. Total CBG is calculated as CBG plus CBGA*0.878 (the molar correction factor for CBGA to CBG conversion). %Decarb. THC and CBD refer to the percentage of Δ9-THC or CBD relative to THCA or CBDA, respectively.

Potency Action Limits
Product Type Action Limit
Concentrates & Vapes Delta-8 concentration cannot exceed 10%
Infused Products

Delta-8 cannot exceed 10% of the maximum THC limits;

Homogeneity must be ≤15% RSD; Variance must be ≤10%

Maximum THC (Sum of Delta-8 and Delta-9) Concentrations for Infused Products (in mg)

 Category

Medical

(Per Dose)

Medical

(Per Container)

Adult-Use

(Per Dose)

Adult-Use

(Per Container)

Infused edibles (gummies, baked goods, drink enhancers, syrup) 50 200 10 200
Medicinal products (capsules, tinctures, oil-based drops) 100 2000 10 200
Medicinal Products not consumed orally (suppositories, tampons, transdermal patches) 100 2000 100 2000
Beverages 10 100 10 100

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information. AU License #: AU-SC-000107; MED License #: SC-000003.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

ARH - LM Iron laboratories ARH - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 1

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

QC Report

Testing Accreditation #: 77802 Test Certificate #: 145632-001
Client Name, Sample Details

Ferndale Maize LLC - STIIIZY (AU-P-000253)
Lake Orion, MI 48359
Sample: Distillate 8
License: AU-P-000253
Type: Tincture
Method: FE04 HPLC-UV
Metrc Test Pkg#: 1A405030002A686000159559
Metrc Source Pkg#: 1A405030002A686000159827

Test Conditions

Prepsheet ID#: MIP240223a
Scale: XS205-MI2
Temp: 22.6 °C
Baro Pressure: 981.2 hPa
Analyst: MEH
Technician: ARH

Sample ID#: 145632

Harvest/Process Date: 02/21/2024
Serving Size (g): 1
Date Received: 02/21/2024
Test Date: 02/23/2024
Valid Through: 02/23/2025
Report Issued: 02/26/2024

Sample #145632
Target Compound Name Method Blank (μg/g) LCS Spike (μg/g) LCS Amount (μg/g) Percent Recovery (%) LCS LCS Duplicate Amount (μg/g) Percent Recovery (%) LCSD Relative Percent Difference (%) QC Flag
Δ9-THC 0 5.20453 5.22838 100.46 5.10729 98.13 2.34%
THCA 0 5.05414 5.06448 100.20 5.06106 100.14 0.07%
Δ8-THC 0 5.57637 5.24372 94.03 5.09336 91.34 2.91%
CBD 0 5.67362 5.25006 92.53 5.25345 92.59 0.06%
CBDA 0 5.25068 5.24893 99.97 5.24408 99.87 0.09%
CBG 0 5.40981 5.34567 98.81 5.36706 99.21 0.40%
CBGA 0 5.19271 5.16148 99.40 5.18547 99.86 0.46%
CBN 0 5.14653 5.19019 100.85 5.17102 100.48 0.37%
CBC 0 5.25272 5.25682 100.08 5.25391 100.02 0.06%
CBCA N/A 0 0 0.00 0 0.00 0% N/A
CBL 0 5.12817 5.27522 102.87 5.26004 102.57 0.29%
THCV 0 5.38851 5.24502 97.34 5.25335 97.49 0.16%
CBDV 0 5.283 5.2636 99.63 5.24844 99.35 0.29%

N.D. = Not Detected

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information. AU License #: AU-SC-000107; MED License #: SC-000003.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

ARH - LM Iron laboratories ARH - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 1